| ID | Action and expected result |
R01 View / control | Verify the operator sees the customer's primary display. Click Notepad and send harmless text, Enter and Backspace. Right-click once. Expect low-frame-rate images and basic input, not video streaming. No dragging, scrolling, clipboard, shortcut chords, UAC or secure-desktop control. NFG's own consent controls must reject remote input. Record errors rather than elevating the app. |
R02 Files | Operator offers a small file. Customer chooses a NEW destination. Compare content; the receiver verifies SHA-256. Decline a second offer. Try an oversized file: it must fail. Try an existing destination: it must not overwrite. Customer clicks Choose a file to send; operator downloads it and verifies content. No directory browsing or arbitrary remote file paths are exposed. Never execute a received file during this test. |
R03 Privacy | Requires Windows 10 build 19041+ or Windows 11. Operator enables privacy; customer confirms EVERY connected display has the black NFG overlay. Verify the operator still sees the desktop, not a black frame. Turn privacy off before input tests. Stop and network-loss tests must remove overlays. This is an experimental overlay, not a hardware display-off or secure-desktop privacy guarantee. Hot-plug, multiple monitors, mixed DPI and fullscreen apps need separate qualification. |
R04 Input blocking | Request one 10-second input-block test. If Windows denies BlockInput, record BLOCKED and the message; do not disable Windows protection. If accepted, local input must resume within 10 seconds. In a NEW session repeat and press Ctrl+Alt+Delete early: input must release. A second block command in the same session must be refused. The input worker releases independently of the UI timer and on worker exit. |
R05 Stop / loss | Test local Stop, Ctrl+Shift+F12, operator Stop and closing the operator tab in separate sessions. Disconnect the customer's network: local display/input must restore after at most 10 seconds without a successful relay response (input block is independently capped at 10 seconds). Closing the operator tab stops the session after about 20 seconds without its heartbeat. No session resumes automatically. Record actual timings. |
R06 Limits / isolation | Approve screen viewing only: control/files/privacy/block must be absent and refused by the API. Approve a subset of a larger request. Let a session expire: v0.17 sessions have no fixed duration; disconnect either endpoint to check heartbeat cleanup. Old codes/consents cannot restart it. Reassign/close the ticket or revoke enrollment during a disposable test: operations must stop on the next check. An unrelated operator must receive an access error. |
R07 Lifecycle | Test Windows lock, sleep/wake and exiting NFG Connect. Session must end and displays/input restore, with fresh consent needed to reconnect. Repeat privacy with each monitor configuration. A hung process is not a passing test: use Ctrl+Alt+Delete / Task Manager, record it as FAIL, and send the observed behavior. |